EX

HMI technologies for all applications in hazardous areas

You Tube
stahl-hmi falcon 125

ET-125-BM  FALCON

  • Text / graphic terminal for serial protocols, Profibus / MPI- basic device in stainless steel enclosure
  • Fast, affordable engineering with SPSPlusWINLite
  • No runtime license costs
  • Character encoding (Latin and Cyrillic)

 

Overview
Technical Data
Operating Principle
Enclosures & Mountings
Accessories
Documents

16 function keys, 8 softkeys, and 23 alphanumeric and system keys make the ET-125-BM the most multi-functional version of the FALCON series operator interfaces – a basic device in stainless steel enclosure. Designed for machine-level operations, the
ET-125-BM is ideally suited for applications in different production areas, onboard ships and in tank farms – certified for hazardous areas, Zone 1, and suitable for use at temperatures ranging from -20 °C up to +70 °C [-4 °F up to +158 °F].

The transflective, 114 mm x 64 mm (4.5 x 2.5") LCD monochrome display with LED backlighting ensures optimal readability, both indoors and outdoors.

The device comes in a rugged plastic enclosure; display and keyboard meet the IP65 standard: they are covered with polyester film that protects against dirt, dust and aggressive atmospheres. The operator interface is available as a front-mounted control panel, or, optionally, in plastic or stainless steel enclosures.

ET-125-BM operator interfaces communicate with PLC over a number of different protocols: serial / MPI / Profibus DP (more options available upon request) – the SPSPlusWIN software allows fast and cost-effective project engineering.

The range of accessories includes intrinsically safe Mifare card readers, Ex-i barcode scanners, field and connection cables and handling modules, and the SPSPlusWIN software.
 
The ET-125-BM is also available as a complete package, including power supply, transmission unit and cabling.

 

Hazardous Areas, Zones IP Ambient temperature range
1
checkmark
2
checkmark
21
checkmark
22
checkmark
Non-Ex

IP65 Operation                                                   -20 °C …+ 70 °C [-4 °F ... +158 °F]

 

Explosion Protection

Certification Marking
ATEX directive 94/9/EG
BVS 03 ATEX E 226
II 2 G EEx ia IIC/IIB T4/T3
II 2 D Ex ia D21 T70°C/80°C
IECEx
BVS 11.0058X
Ex ia IIC/IIB T4/T3 Gb
Ex ia IIIC T70°C/80°C Db
TR (Russia / Kazakhstan / Belarus)
RU C-DE.ГБ04.B00334
1Ex ia IIC/IIB "T4, T3" Gb
Ex ia IIIC "T70°C, T80°C" Db
PESO (India)
A/P/HQ/MH/104/3217(P327856)
CCE identification number
P327856/1 

Highlights

Hardware

  • Ready-to-use HMI suitable for standard automation tasks and PLC control
  • Ideal for machine operation, and tank farm applications
  • Barcode / Mifare reader connectable
  • Pre-installed SPSPlusWIN software for fast and cost-saving engineering
  • Rugged design, suitable for temperatures ranging between
    -20 °C up to +70 °C [-4 °F up to +158 °F]

Firmware / Software

  • Pre-installed engineering software SPSPlusWIN – saves runtime costs
  • Excel / languages import / export functions, and Ethernet up- / download
  • Multilingual user interface
  • Multiple functions, e. g. bar graph indicator, analog and alarm display

Technical Data

Mounting design Front panel mounting
Display 11.4 x 6.4 cm (4.5 x 2.5") LCD monochrome graphics display
Transflective, sunlight-readable display
240 x 128 pixels
Contrast control by key combination
Backlighting LED technology with additional power supply
Service life 50,000 h at +25 °C [+77 °F]
Display function keys 16 function keys (custom labels possible)
8 soft keys
Cursor keys
10 alphanumeric keys
9 system keys
Polyester film on FR4
LEDs 5 LEDs at the display (STOP, COM, ONLINE, ALARM, INFO)
12 LEDs at the function keys
Operating system SPS-Mode
Languages

4 system languages (de, en, fr, nl)

Interfaces 1 x serial RS-422 bus-compatible (via 9185/11-45-xx)
Optional interfaces
1 x RSi for readers (Barcode scanner, RFID Reader)
1 x RS-232 / RS-422 / RS-485 (via 9185/11-45-xx)
1 x Profibus DP (via 9185/11-46-xx)
1 x MPI (via 9185/11-45-xx + MPI box))
Dimensions (W x H x D) 312 x 192 x 80 mm (12.28 x 7.56 x 3.42")
Cutout 300 x 180 mm (11.81 x 7.09")
Weight 1.3 kg (2.9 lbs)
Power supply 10.8 VDC (8 up to 12.5 VDC); via 9143/10-xx; max. 180 mA
Permissible ambient temperature ranges Operation  -20 °C up to +70 °C [ -4 °F up to +158 °F]
                 (-20 °C up to +60 °C [ -4 °F up to +140 °F] at T4)
Storage     -30 °C up to +80 °C [-22 °F up to +176 °F]
Relative humidity 90 % at +40 °C [+104 °F], non condensing
Vibration Operation:            3 up to 22 Hz: 1 mm (0.04")
                           22 up to 500 Hz: 9.8 m/s2 = 1 g (32 ft/s2 = 0.03 oz)
Transportation:    3 up to 9 Hz: 3.5 mm (0.14")
                             9 up to 500 Hz: 9.8 m/s2 = 1 g (32 ft/s2 = 0.03 oz)
Shock Operation:         15 g / 11 ms (0.52 oz/11 ms)
Transportation:  25 g / 6 ms (0.88 oz/6 ms)
Material front side Frame: Aluminum with polyester film, sealing
Material back side Stainless steel
Ingress protection Front side IP65, back side IP20

We reserve the right to make any changes at any time according to techological progress or further development.

 

fp exicom falcon

Standard Enclosures

FALCON-Standard-1FALCON-Standard-2

 

Customized Enclosures

FALCON-Custom-2FALCON-Custom-1Customized Enclosures?

Please click here.

FALCON interface converter S7 MPI bus adapter

 mpi box 000834

Design Order number
S7 MPI bus adapter with RS-232 interface, DIN rail mounting, no handling block required MPI-Box-SSW7-RK512-RS-232

FALCON stainless steel enclosure V4A for ET-125

hsg-et-125-wcr-front 300dpi

Design Order number
Dimensions (WxHxD) 360 x 360 x 91 mm (14.2 x 14.2 x 3.9"),
with cover cut-out
HSG-ET-125-V4A

FALCON engineering software

SPSPlusWIN

Design Order number
Engineering software for all Falcon operator interfaces       SPSPlusWIN-LITE5.xx
Update to current version SPSPlusWIN-LITE5. xx-Update

FALCON 9143 power supply for ET-65/-75/-125/-125-A

 stromversorgung

Design Order number
Power supply, 24 V DC; DIN rail mounting 9143 / 10-114-200-10
Power supply, 85 - 253 V AC; DIN rail mounting       9143 / 10-114-200-20

FALCON interface converter Ethernet

 FALCON Schnittstellenkonverter

Design Order number
Fieldbus Bridge from Modbus TCP to RTU in addition to 9185/11-45-10      SK-FB-Cobox

FALCON stainless steel enclosure V4A with breather for ET-125

hsg-et-125-wcr-front 300dpi

Design Order number
Dimensions (WxHxD) 360 x 360 x 91 mm (14.2 x 14.2 x 3.9"),
with cover cut-out, incl. breather to prevent condensation
HSG-ET-125-V4A-B

FALCON connection cable to Fieldbus insulator

 FALCON Verbindungskabel Felbus-Trennuebertragen

Design Order number
Fieldbus Insulator => PC / SPS, MT-65 => PC             VB-300

FALCON Connection cable

 FALCON-Verbindungskabel-1-1FALCON-Verbindungskabel-1-2

Design Order number
9185 => MPI-Box VB-301
9185 => Terminal block, blue           VB-299

FALCON Field cable

 FALCON-Verbindungskabel-1-2

Design Order number
blue, LIYCY 6 x 2 x 0,75 mm 2, price per meter     VB-6x2x0,75-bl

FALCON Insulator

9185

Design Order number
Fieldbus Insulator, serial, DIN rail mounting 9185/11-45-10
Fieldbus Bridge Profibus DP, DIN rail mounting      9185/11-46-10

Operating Instructions (OI):


The R. STAHL HMI operating instructions provide all information relevant to ensure compliance with explosion protection requirements (certifications and marking, safety-related data, EC-Declaration of conformity), as well as basic information on the connection and operation of any HMI product revision.

Device   Document
version
Hardware
version
Language Size

Accessories   Document
version
Hardware
version
Language Size

 

Data sheets (DS)


The data sheets contain key information on each device. Depending on the device in question, the information consists of a general description, installation and operation options, different models and order versions and the device’s technical data. Any available accessories are also listed.

Device   Document
version
Hardware
version
Language Size
ET-65-B 02.02.00 Englisch 274.02 KB
Data sheet
for Zone 1, 21, 2, 22
ET-75-B 02.02.00 Englisch 254.07 KB
Data sheet
for Zone 1, 21, 2, 22
ET-125-B 02.02.00 Englisch 264.8 KB
Data sheet
for zone 1, 21, 2, 22
ET-125-BM 02.03.00 Englisch 264.7 KB
Data sheet
for Zone 1, 21, 2, 22

 

Certification package (CE)


The certification package includes all relevant certificates related to the respective product revision—for safety reasons, please only use the respective certification package. (Any other combination of certificates may affect the guidelines for explosion protection).

Device   Document
version
Hardware
version
Language Size

Accessories   Document
version
Hardware
version
Language Size

For accessory certificates that are not listed here, please refer to the operating instructions of the respective accessory.
Should you need any of the certificates separately as PDF file, please contact our Technical Support at: +49 (0)221 59808-59.

 

Material resistance (MR)


The manual for material resistance contains information on the resistance of the devices to various environmental factors.

Device   Document
version
Hardware
version
Language Size
Material resistance ET-65-B, ET-75-B, ET-125-B und ET-125-BM 02.05.00 Englisch 139.01 KB
Material resistance
for devices ET-65-B, ET-75-B, ET-125-B und ET-125-BM
Material resistance ET-65-B, ET-75-B, ET-125-B und ET-125-BM 02.05.00 Deutsch 128.33 KB
Material resistance
for devices ET-65-B, ET-75-B, ET-125-B und ET-125-BM

 

 

 

 

 

 

 

 

 

FaLang translation system by Faboba