EX

HMI technologies for all applications in hazardous areas

You Tube
et-mt-306 72dpi rgb kl

MT-306     10.4" (640 x 480)

  • Multi-lingual machine-level terminal for medium-sized automation tasks
  • Proprietary operating system for enhanced security
  • Modern Ethernet protocols:
    Ethernet IP, Modbus TCP, Profinet-interface (S7 / RFC1006)
  • Cost-saving SPSPlusWIN software, including many functions
  • Remote access to network and web server

Overview
Technical Data
Operating Principle
Enclosures & Mountings
Accessories
Documents

The intelligent MT-306 operator interface is the optimal solution for complex machine-level operations and visualization tasks, including PLC programming, and suitable for hazardous areas, Zone 2, 22. The terminal is used worldwide in a variety of applications, for example in package units, and for logistics and automation tasks in tank farms.

The MT-306 terminal has a fast processor, a high bright 10.4" TFT display, and can be configured with the optional SPSPlusWIN software for fast and cost-effective project engineering. Suitable for international applications, this software has a multi-lingual user interface, language import and export, and supports international character set standards. Functionalities inlcude recipe management, Microsoft Excel import / export, Ethernet upload and download, and intelligent page navigation. Designed as a "closed unit" with proprietary real-time operating system, the MT-306 are protected against external manipulations.

Communication between terminal and automation systems is realized over Ethernet IP, Modbus TCP, Profinet-interface (S7 / RFC1006) or Modbus, MPI and other serial interfaces. Optional integrated card readers for user authentication include Mifare and ProxPro card readers.

AMD LX 800 300 MHz processors ensure fast data processing; the absence of moving parts (e.g. ventilator, hard disk) enables realiable operation and prevents the MT-306 from overheating.

The MT-306 is operated via an analog-resistive touch screen, with 12 customizable function keys, 10 softkeys and 23 alphanumeric keys.

The rugged MT-306 EAGLE terminal is suitable for applications in harsh environments, at temperatures ranging from
-20 °C up to +55 °C [-4 °F up to +131 °F] (with heater -30 °C [-22 °F]) and certified according to ATEX,  IECEx, NEC / UL, CEC / CSA, Marine approval DNV, LR (and more).

 

Hazardous Areas, Zones IP Ambient temperature range
1 2
checkmark
21 22
checkmark
Non-Ex IP66 Operation                                                      -20 °C … +55 °C   [  -4 °F up to +131 °F]
Operation with heater                                  -30 °C … +55 °C   [-22 °F up to +131 °F]

 

OS MT-306-FX en Englisch 0 B

Operator Interface Operator Station
1x FX Multimode
for Zone 2, 22

OS MT-306-TX en Englisch 0 B
Operator Interface Operator Station
1x Twisted Pair (TX) Ethernet
for Zone 2, 22
PM MT-306-FX en Englisch 0 B

Operator Interface panel mounting
1x FX Multimode
for Zone 2, 22

PM MT-306-TX en Englisch 0 B
Operator Interface panel mounting
1x Twisted Pair (TX) Ethernet
for Zone 2, 22


We reserve the right to make any changes at any time according to techological progress or further development.

 

fp exicom 300series eagle

Enclosure drawings (Catalogue German / English)

Standard Enclosures

10-15-housinghsg-x36-al-rf01-03

 

Mounting Options

STAHL-HMI Montage-EAGEL-bottom RGB 72dpiSTAHL-HMI Montage-EAGEL-wall-top RGB 72dpiSTAHL-HMI Montage-EAGEL-wall RGB 72dpi

 

Customized Enclosures

EAGLE Customized-HousingCustomized Enclosures?

Please click here.



Interface modules

mpi box 000834

Design   Order number
S7 MPI bus adapter with RS-422 interface, DIN rail mounting, no handling block required         MPI-Box-SSW7-RK512-RS-422

SERIES 300 / 400 / 500 (ET-/MT-xx6) media converter / switch

9721Sk-KJ1710

Design   Order number
Single Port Fiber Switch
from 1 x 10/100Base-TX to 1 x 100Base-FX
FO multi-mode 50 (62.5) / 125 μm
Cable lenght 5000 (4000) m
1x RJ45, 1x SC connector
  9721/13-11-14
Single Port Fibre Switch from
10/100Base-TX (4 x RJ45 ports) to
100Base-FX „Ex op is“ (1 x optical fibre port MTRJ),
incl. patch cable VB-SC-MTRJ
  SK-KJ1710
4 Port Fibre Switch from
100Base-FX „Ex op is“ (4 x optical fibre ports MTRJ) to
10/100 Base-TX (1 x RJ45 port),
incl. 4 x patch cable VB-SC-MTRJ
  SK-KJ1740

SERIES 300 / 400 / 500 (ET-/MT-xx6) keyboards (I.S.)

tastatur

Design   Order number
in QWERTZ, 105 keys, PS2 interface        KBDi-PS2-QZ
in QWERTY, 105 keys, PS2 interface   KBDi-PS2-QY
in AZERTY, 105 keys, PS2 interface   KBDi-PS2-AY


      Operating Instructions keyboard KBD(i) (German / English)

SERIES 300 Mifare card reader, intrinsically safe, proximity

kartenleser beruehrungslos

Design   Ordernumber
Mifare card reader (I.S.), proximity, connectable to RSi interface of ET-/MT-3x6 devices    
- Protocol based CRYPT   RFIDi-RDR-2-MIF


      Operating Instructions RFID (German / English)

Mifare cards for Mifare card reader

mifare stahl

Design   Order number
10 Mifare access cards, proximity
1K S50 - ISO 14443,
 Front: vinyl, glossy white
R. STAHL logo on back, inkjet site code and card number
Coding:
Client number 16 bit: 0
Site/facility code 16 bit: 1 and serial card number from 001 to 010
Cards externally printed with site code and card number     
00001 - 00001 to 00010
  Mifare-1K-S50-ISO14443-S-10
100 Mifare access cards, as above,
but card number from 1 to 100
  Mifare-1K-S50-ISO14443-S-100

SERIES 200 / 300 / 400 / 500 / 600 barcode handheld scanner IDMx6x (I.S.)

KabelgebundenerHandscanner Freigestellt nb001

Design   Order number
Handheld barcode scanner zone 1, 2, 21, 22, wired, without cable, 1D barcode, 630 nm,
reading speed 500 Hz, reading distance 20 … 850 mm
  IDM160-ex-b
Handheld barcode scanner zone 1, 2, 21, 22, wired, without cable, 1D barcode, 630 nm, stacked PDF barcodes,
reading speed 500 Hz, reading distance 20 … 850 mm
  IDM160-PDF-ex-b
Handheld barcode scanner zone 1, 2, 21, 22, wired, without cable, 1D and 2D barcode, 630 nm, stacked PDF barcodes,
reading speed 60 Hz, reading distance 30 … 160 mm
  IDM260-ex


                                                Operating Instructions IDMx6x scanner (German / English)

SERIES 200 / 300 / 400 / 500 / 600 barcode bluetooth scanner IDMx6x-BT (I.S.)

HandscannerBT Freigestellt nb001

Design   Order number
Handheld barcode scanner zone 1, 2, 21, 22, bluetooth, wireless, 1D barcode, 630 nm,
reading speed 500 Hz, reading distance 20 … 850 mm
  IDM161-BT-ex
Handheld barcode scanner zone 1, 2, 21, 22, bluetooth, wireless, 1D barcode, 630 nm, stacked PDF barcodes, reading speed 500 Hz, reading distance 20 … 850 mm   IDM161-BT-PDF-ex
Handheld barcode scanner zone 1, 2, 21, 22, bluetooth, wireless, 1D and 2D barcode, 630 nm, stacked PDF barcodes,
reading speed 60 Hz, reading distance 30 … 160 mm
  IDM261-BT-ex


                                                Operating Instructions IDMx6x scanner (German / English)

SERIES 300 / 400 / 500 (ET-/MT-xx6) supply module for reader devices

 Versorgungsmodul BCS-Leser

Design   Order number
Version for barcode reader:
Operating voltage AC: 100 - 240 VAC,
Output for reader 5.4 V (Ex i )
Communication interface: RS-232
  ReaderBox-054-AC-RS232
Version for barcode reader:
Operating voltage DC: 12 - 30 VDC,
Output for reader 5.4 V (Ex i)
Communication interface: RS-232
  ReaderBox-054-DC-RS232


                                                Operating Instructions ReaderBox (German / English)

SERIES 300 / 400 / 500 USBi-Drive

speicher

Design   Order number
USB stick, intrinsically safe, 16 GB   USBi-Drive-16GB
USB stick, intrinsically safe, 16 GB, with Recovery and Backup function   USBi-Drive-16GB-Recovery
USB stick, 16 GB, with Recovery and Backup function   USB-Drive-16GB-Recovery
USB extension and bracket with USB plug-in coupling for front IP65 or mounting in field enclosure..   VB-USB-Plug
The USBi-Drive can not be used with devices from ET-/MT-xx7 SERIES !


                                                Operating Instructions USBi-Drive (German / English)

SERIES 200 / 300 / FALCON engineering software

SPSPlusWIN

Design   Order number
Engineering software for SERIES 200 / 300 (EAGLE) and FALCON Operator Interfaces         SPSPlusWIN-5.xx
Update to current version   SPSPlusWIN-Update-5.xx

SERIES 300 / 400 / 500 field cable

 

Design   Order number
Patch cable MTRJ => SC (SK-KJ1710 --> EXICOM)   VB-SC-MTRJ
Patch cable 3 m (118.11"), 2 x RJ45 (SK-KJ1710 --> PC / plug)   VB-SFTP-CAT5-Patch-3,0Patch
Patch cable 3 m (118.11"), open => RJ45 (EAGLE / Open HMI => plug)   VB-TP-CAT5-Exe-RJ45-Patch
Field cable copper, CAT5E, AWG22 (material sold by the metre)   VB-TP-CAT5-AWG22
RJ45 plug, metal, can be assembled in the field   VB-RJ45-PLUG-180
Extension scanner interface to flange socket M12   VB-BC-3
Adapter for DIN rail mounting SC --> SC   VB-SC-SC-jack
MilTac breakout optical fibre cable, basic length 2 m (78.74"), with SC plug both ends   VB-FO-MIL-SC-SC-2m
MilTac breakout optical fibre cable, additional length in metres   VB-FO-MIL-xm
Indoor breakout optical fibre cable, basic length 2 m (78.74"), with SC plug both ends   VB-FO-SC-SC-62V04G-2m
Indoor breakout optical fibre cable, additional length in metres      VB-FO-62V04G-xm

OS MT-306-FX en Englisch 0 B

Operator Interface Operator Station
1x FX Multimode
for Zone 2, 22

OS MT-306-TX en Englisch 0 B
Operator Interface Operator Station
1x Twisted Pair (TX) Ethernet
for Zone 2, 22
PM MT-306-FX en Englisch 0 B

Operator Interface panel mounting
1x FX Multimode
for Zone 2, 22

PM MT-306-TX en Englisch 0 B
Operator Interface panel mounting
1x Twisted Pair (TX) Ethernet
for Zone 2, 22

FaLang translation system by Faboba