EX

HMI technologies for all applications in hazardous areas

You Tube
et-mt-it-536 72dpi rgb kl

MT-536     15“ (1024 x 768)

  • RDP and VNC possible, as well as LAN, WLAN and Internet
  • With Remote firmware for extra system security
  • Access from one operating station to one / several PCs
  • Affordable hardware and central data administration
  • Touch screen as standard

 

Overview
Technical Data
Operating Principle
Enclosures & Mountings
Accessories
Documents

15" Thin Clients are often used for medium-sized, machine-level operations within the network architecture - certified for hazardous areas, Zone 2, 22. Thin Clients are the best solution when it comes to flexible data access - via the IP address it is possible to access any PC or any network from any client, thus providing the operator with the best possible flexibility on site. The MT-536 communicates over standard Ethernet (TCP/IP) or fiber optic, thus enabling RDP and VNC, as well as LAN, WLAN and Internet. (Advantages virtualization)

All HMIs of the MT-500 series come with our special Remote HMI firmware for enhanced Thin Client security. Designed as a "closed system" with the highest level of security and protection against external manipulations, this Remote HMI firmware controls network communications, password assignment, block operator input, and IP address assigment.
(Advantages Remote firmware)
In the rare case of a system failure, the BACKUP / RECOVERY solution via USB stick allows to immediately restore the original state.

For drilling rig or outdoor applications, we have developed the innovative sunlight readable display with pole filter system that blocks out distracting reflections and glare, thus ensuring best screen readability even in bright sunlight.

The MT-536 with high bright 15" LED-backlit display comes standard with intuitive touch screen; hardware keyboard, trackball, mouse, joystick, and touch pad are also available.

Thanks to the modern heat pipe technology combined with protection screen and enclosure heater, the Thin Client operates at temperatures ranging between -20 °C up to +55 °C [-4 °F up to +131 °F] (+50 °C [+122 °F] permanent operation). 
All Thin Clients have a modular structure, so that in the rare case of a failure only the faulty component has to be exchanged.

The MT-536 is extremely rugged, without any rotating parts, suitable for reliable 24/7 operation, and certified according to international standards: ATEX,  IECEx, NEC, CEC, Marine approval DNV, LR (and more).

 

Hazardous Areas, Zones IP Ambient temperature range
1 2
checkmark
21 22
checkmark
Non-Ex IP66 Operation                                                      -20 °C … +55 °C   [  -4 °F up to +131 °F]
                                                                       (permanent operation +50 °C [+122 °F])
Operation with heater                                  -30 °C … +55 °C   [-22 °F up to +131 °F]

 

Similar products

 

OS MT-536-FX en Englisch 0 B

Operator Interface Operator Station
1x FX Multimode
for Zone 1, 2, 21, 22

OS MT-536-TX en Englisch 0 B
Operator Interface Operator Station
1x Twisted Pair (TX) Ethernet
for Zone 2, 22
PM MT-536-FX en Englisch 0 B

Operator Interface panel mounting
1x FX Multimode
for Zone 2, 22

PM MT-536-TX en Englisch 0 B
Operator Interface panel mounting
1x Twisted Pair (TX) Ethernet
for Zone 2, 22


We reserve the right to make any changes at any time according to techological progress or further development.

 

fp exicom 500series


Enclosure drawings (Catalogue German / English)

Standard enclosures

10-15-housinghsg-x36-al-rf01-03

 

Mounting options

montagevarianten

 

Customized enclosures

16560093 rev00-hsg-x56-vxa-crs-desk-incl-keybhsg_xx6_v2a_cfr_w_srCustomized Enclosures?

Please click here.

SERIES 300 / 400 / 500 (ET-/MT-xx6) media converter / switch

9721Sk-KJ1710

Design   Order number
Single Port Fiber Switch
from 1 x 10/100Base-TX to 1 x 100Base-FX
FO multi-mode 50 (62.5) / 125 μm
Cable lenght 5000 (4000) m
1x RJ45, 1x SC connector
  9721/13-11-14
Single Port Fibre Switch from
10/100Base-TX (4 x RJ45 ports) to
100Base-FX „Ex op is“ (1 x optical fibre port MTRJ),
incl. patch cable VB-SC-MTRJ
  SK-KJ1710
4 Port Fibre Switch from
100Base-FX „Ex op is“ (4 x optical fibre ports MTRJ) to
10/100 Base-TX (1 x RJ45 port),
incl. 4 x patch cable VB-SC-MTRJ
  SK-KJ1740

SERIES 300 / 400 / 500 (ET-/MT-xx6) keyboards (I.S.)

tastatur

Design   Order number
in QWERTZ, 105 keys, PS2 interface        KBDi-PS2-QZ
in QWERTY, 105 keys, PS2 interface   KBDi-PS2-QY
in AZERTY, 105 keys, PS2 interface   KBDi-PS2-AY


      Operating Instructions keyboard KBD(i) (German / English)

SERIES 400 / 500 (ET-/MT-xx6) keyboards (I.S.) with integrated trackball

tastatur tb

Design   Order number
in QWERTZ, 107 keys, PS2 interface, trackball   KBDi-TB50-PS2-QZ
in QWERTY, 107 keys, PS2 interface, trackball        KBDi-TB50-PS2-QY
in AZERTY, 107 keys, PS2 interface, trackball   KBDi-TB50-PS2-AY


      Operating Instructions keyboard KBD(i) (German / English)

SERIES 400 / 500 (ET-/MT-xx6) keyboards (I.S.) with integrated joystick

tastatur js

Design   Order number
in QWERTZ, 107 keys, PS2 interface, joystick         KBDi-JS-PS2-QZ
in QWERTY, 107 keys, PS2 interface, joystick   KBDi-JS-PS2-QY
in AZERTY, 107 keys, PS2 interface, joystick   KBDi-JS-PS2-AY


      Operating Instructions keyboard KBD(i) (German / English)

SERIES 400 / 500 (ET-/MT-xx6) trackball (I.S.)

trackball

Design   Order number
Diameter 50 mm, PS2 interface         TB-i50-PS2


     Operating Instructions trackball TB(i) (German / English)

SERIES 200 / 300 / 400 / 500 / 600 card reader (I.S.), proximity

kartenleser beruehrungslos

Design   Order number
Mifare card reader I.S., proximity, connectable to RSi interface of ET-/MT-xx6 devices or with ReaderBox-104 to ET-/MT-xx7 and SERIES 200    
- Protocol based CRYPT   RFIDi-RDR-2-MIF-CRYPT
- ASCII protocol   RFIDi-RDR-2-MIF-ASC


                                                Operating Instructions RFID (German / English)

Mifare cards for Mifare card reader

mifare stahl

Design   Order number
10 Mifare access cards, proximity
1K S50 - ISO 14443,
 Front: vinyl, glossy white
R. STAHL logo on back, inkjet site code and card number
Coding:
Client number 16 bit: 0
Site/facility code 16 bit: 1 and serial card number from 001 to 010
Cards externally printed with site code and card number     
00001 - 00001 to 00010
  Mifare-1K-S50-ISO14443-S-10
100 Mifare access cards, as above,
but card number from 1 to 100
  Mifare-1K-S50-ISO14443-S-100

SERIES 200 / 300 / 400 / 500 / 600 barcode handheld scanner IDMx6x (I.S.)

KabelgebundenerHandscanner Freigestellt nb001

Design   Order number
Handheld barcode scanner zone 1, 2, 21, 22, wired, without cable, 1D barcode, 630 nm,
reading speed 500 Hz, reading distance 20 … 850 mm
  IDM160-ex-b
Handheld barcode scanner zone 1, 2, 21, 22, wired, without cable, 1D barcode, 630 nm, stacked PDF barcodes,
reading speed 500 Hz, reading distance 20 … 850 mm
  IDM160-PDF-ex-b
Handheld barcode scanner zone 1, 2, 21, 22, wired, without cable, 1D and 2D barcode, 630 nm, stacked PDF barcodes,
reading speed 60 Hz, reading distance 30 … 160 mm
  IDM260-ex


                                                Operating Instructions IDMx6x scanner (German / English)

SERIES 200 / 300 / 400 / 500 / 600 barcode bluetooth scanner IDMx6x-BT (I.S.)

HandscannerBT Freigestellt nb001

Design   Order number
Handheld barcode scanner zone 1, 2, 21, 22, bluetooth, wireless, 1D barcode, 630 nm,
reading speed 500 Hz, reading distance 20 … 850 mm
  IDM161-BT-ex
Handheld barcode scanner zone 1, 2, 21, 22, bluetooth, wireless, 1D barcode, 630 nm, stacked PDF barcodes, reading speed 500 Hz, reading distance 20 … 850 mm   IDM161-BT-PDF-ex
Handheld barcode scanner zone 1, 2, 21, 22, bluetooth, wireless, 1D and 2D barcode, 630 nm, stacked PDF barcodes,
reading speed 60 Hz, reading distance 30 … 160 mm
  IDM261-BT-ex


                                                Operating Instructions IDMx6x scanner (German / English)

SERIES 300 / 400 / 500 (ET-/MT-xx6) supply module for reader devices

 Versorgungsmodul BCS-Leser

Design   Order number
Version for barcode reader:
Operating voltage AC: 100 - 240 VAC,
Output for reader 5.4 V (Ex i )
Communication interface: RS-232
  ReaderBox-054-AC-RS232
Version for barcode reader:
Operating voltage DC: 12 - 30 VDC,
Output for reader 5.4 V (Ex i)
Communication interface: RS-232
  ReaderBox-054-DC-RS232


                                                Operating Instructions ReaderBox (German / English)

SERIES 300 / 400 / 500 USBi-Drive

speicher

Design   Order number
USB stick, intrinsically safe, 16 GB   USBi-Drive-16GB
USB stick, intrinsically safe, 16 GB, with Recovery and Backup function   USBi-Drive-16GB-Recovery
USB stick, 16 GB, with Recovery and Backup function   USB-Drive-16GB-Recovery
USB extension and bracket with USB plug-in coupling for front IP65 or mounting in field enclosure..   VB-USB-Plug
The USBi-Drive can not be used with devices from ET-/MT-xx7 SERIES !


                                                Operating Instructions USBi-Drive (German / English)

SERIES 500 (ET-/MT-5x6) KVM box

kvm box

Design   Order number
Digital KVM switch for ET-/MT-5x6
KVM ports to PC:
• 2 x PS2 socket (keyboard / mouse)
• 1 x USB-B socket (keyboard / mouse to PC)
• 1 x USB-B socket (virtual media to PC)
• 1 x DVI-I socket (screen, DVI / VGA)
• 1 x TRS socket (audio)
Remote HMI connection:
• 10Base-T, 100Base-TX Ethernet
  5x6-KVM-digital

SERIES 500 KVM Box

600px alifdual front tx lid VNC

600px ipeps digital face

Design   Order number
Digital KVM over IP transmission unit
Remote monitoring and control, without software
installation
Multi-user system (up to 16 users simultaneously)
Video resolution up to 2560 x 1600 pixels
Connection to the PC via DVI / USB
Data transfer via CAT cable up to 100 m
  KVM-INFINITY-DUAL-2112T
Digitale KVM over IP transmission unit
Remote monitoring and control, Peer-to-Peer
Video resolution up to 1920 x 1200 pixels
Connection to the PC via DVI / USB
Data transfer via CAT cable up to 100 m
  KVM-DIGITAL-IPEPS

SERIES 500 DIN rail kit for KVM box

Hutschienenkit

Design   Order number
Assembly kit DIN rail        5x6-KVM-DINrailKit

SERIES 500 assembly kit 1 KVM box

 Montagekit1

Design   Order number
Assembly kit 48 cm rack (19“ rack) installation angle for 1 KVM box        5x6-KVM-RackMountKit-1

SERIES 500 assembly kit 2 KVM boxes

 Montagekit2

Design   Order number
Assembly kit 48 cm rack (19“ rack) installation angle for 2 KVM boxes        5x6-KVM-RackMountKit-2

SERIES 300 / 400 / 500 field cable

 

Design   Order number
Patch cable MTRJ => SC (SK-KJ1710 --> EXICOM)   VB-SC-MTRJ
Patch cable 3 m (118.11"), 2 x RJ45 (SK-KJ1710 --> PC / plug)   VB-SFTP-CAT5-Patch-3,0Patch
Patch cable 3 m (118.11"), open => RJ45 (EAGLE / Open HMI => plug)   VB-TP-CAT5-Exe-RJ45-Patch
Field cable copper, CAT5E, AWG22 (material sold by the metre)   VB-TP-CAT5-AWG22
RJ45 plug, metal, can be assembled in the field   VB-RJ45-PLUG-180
Extension scanner interface to flange socket M12   VB-BC-3
Adapter for DIN rail mounting SC --> SC   VB-SC-SC-jack
MilTac breakout optical fibre cable, basic length 2 m (78.74"), with SC plug both ends   VB-FO-MIL-SC-SC-2m
MilTac breakout optical fibre cable, additional length in metres   VB-FO-MIL-xm
Indoor breakout optical fibre cable, basic length 2 m (78.74"), with SC plug both ends   VB-FO-SC-SC-62V04G-2m
Indoor breakout optical fibre cable, additional length in metres      VB-FO-62V04G-xm

OS MT-536-FX en Englisch 0 B

Operator Interface Operator Station
1x FX Multimode
for Zone 1, 2, 21, 22

OS MT-536-TX en Englisch 0 B
Operator Interface Operator Station
1x Twisted Pair (TX) Ethernet
for Zone 2, 22
PM MT-536-FX en Englisch 0 B

Operator Interface panel mounting
1x FX Multimode
for Zone 2, 22

PM MT-536-TX en Englisch 0 B
Operator Interface panel mounting
1x Twisted Pair (TX) Ethernet
for Zone 2, 22

 